Corresponding author: Zlatina Kokanova-Nedialkova ( zlatina.kokanova@pharmfac.mu-sofia.bg ) Academic editor: Plamen Peikov
© 2021 Zlatina Kokanova-Nedialkova, Paraskev Nedialkov.
This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Citation:
Kokanova-Nedialkova Z, Nedialkov P (2021) Validated UHPLC-HRMS method for simultaneous quantification of six saponins from the roots of the wild spinach (Chenopodium bonus-henricus L.). Pharmacia 68(2): 321-325. https://doi.org/10.3897/pharmacia.68.e63722
|
An UHPLC-HRMS method for simultaneous quantification of six saponins from the roots of Chenopodium bonus-henricus L. was developed and validated. All calibration curves showed very good linear regressions and the correlation coefficients were R2 > 0.99. The limits of detection and quantitation limits ranged from 0.20 to 0.61 ng/mL and from 0.61 to 1.85 ng/mL, respectively. A good agreement between the spiked and determined concentrations indicated acceptable accuracy. Besides, the related compounds showed overall recoveries ranging from 95.38% to 103.47% with RSD ranging from 0.64% to 4.25%. The intra-day and inter-day precision were determined by analyzing the retention times and recovery of the calibrants. The saponins of medicagenic acid (3), 2β-hydroxygypsogenin (4), and bayogenin (2) were the predominant compounds and reached 15.01%, 3.87%, 2.41% in the crude EtOH extract and 43.69%, 16.16%, 10.07% in the purified EtOH extract, respectively.
Amaranthaceae, Chenopodium bonus-henricus, quantification, saponins, UHPLC-HRMS
The genus Chenopodium (Amaranthaceae) numbers a wide range of species (more than 200) and is native to all the continents with exception of Antarctica as well as in some distant archipelagoes (such as Juan Fernandez, New Zealand, and Hawaii) (
UHPLC-HRMS analysis was performed using a Thermo Scientific Dionex Ultimate 3000 RSLC (Germering, Germany) consisting of 6-channel degasser SRD-3600, high-pressure gradient pump HPG-3400RS, autosampler WPS-3000TRS, and column compartment TCC-3000RS coupled to Thermo Scientific Q Exactive Plus (Bremen, Germany) mass spectrometer. Column chromatography (CC) was achieved on Diaion HP-20 (Supelco, USA). All the reagents used were of analytical grade. The main saponins (purity 95–96%), Bonushenricoside A (3-O-α-L-arabinopyranosyl-phytolaccagenin-28-O-β-D-glucopyranosyl ester) (1), 3-O-β-glucuronopyranosyl-bayogenin-28-O-β-glucopyranosyl ester (2), 3-O-β-glucuronopyranosyl-medicagenic acid-28-β-xylopyranosyl(1→4)-α-rhamnopyranosyl(1→2)-α-arabinopyranosyl ester (3), 3-O-β-glucuronopyranosyl-2β-hydroxygypsogenin-28-O-β-glucopyranosyl ester (4), 3-O-L-α-arabinopyranosyl-bayogenin-28-O-β-glucopyranosyl ester (5), Bonushenricoside B (3-O-β-D-glucuronopyranosyl-2β-hydroxyoleanoic acid-28-O-β-D-glucopyranosyl ester)(6) were previously isolated from the roots of C. bonus-henricus L. (
The roots of Chenopodium bonus-henricus L. were collected from Beglica, Western Rhodopes, Bulgaria in September 2017. The plant was identified by P. Nedialkov and a voucher specimen from the plant population (No. SOM-Co-169848) was deposited at the National Herbarium, Bulgarian Academy of Sciences, Sofia, Bulgaria.
The roots of C. bonus-henricus were dried in the shade, and the powdered plant material (200 mg) was extracted with 70 vol. % EtOH (2 × 30 mL) by ultrasonic-assisted extraction. After filtration, the EtOH extracts were diluted to 100 mL 70 vol. % EtOH. The resulting solution was filtered again and the first 10 mL were removed. An aliquot (10 mL) of this solution was evaporated to dryness, then dissolved in water and further purified by solid-phase extraction over RP18. The sorbent was first washed with H2O, then eluted with 70 vol. % EtOH (12 × 500 µL) in a 10.0 mL volumetric flask and diluted to the nominal volume with the same solvent (solution A). Subsequently, 1 mL of solution A was diluted to 100 mL 70 vol. % EtOH (solution B). Solution B was used for LC-MS quantification of saponins in the crude EtOH extract (CEE).
The powdered plant material (40 g) was extracted subsequently with absolute EtOH (5 × 300 mL) and 70 vol. % EtOH (5 × 300 mL) by ultrasonic-assisted extraction. After filtration, the EtOH extracts were combined and the solvent was evaporated under reduced pressure to give 20.43 g white-yellow residue. For further purification, EtOH extract was dissolved in 200 mL H2O and then subjected to CC over Diaion HP-20 (30 × 4 cm) with H2O (1 L) and 90 vol. % MeOH (1 L). The 90% MeOH eluate was evaporated to dryness in a rotary evaporator to give 6.70 g whitish to creamy powder referred to as a PEE that was further used for LC-MS quantification of saponins. PEE (50 mg) was dissolved in 50 mL 70 vol. % EtOH (solution A). Subsequently, 5 mL of solution A was diluted to 25 mL 70 vol. % EtOH (solution B). Further, 1 mL of solution B was diluted to 100 mL 70 vol. % EtOH (solution C). Solution C was used for LC-MS quantification of saponins.
UHPLC separations were performed on a Kromasil Eternity XT C18 column (AkzoNobel, Sweeden) (2.1 × 100 mm, 1.8 μm) equipped with precolumn SecurityGuard ULTRA UHPLC EVO C18 (Phenomenex, USA) at 40 °C. Each chromatographic run was carried out with a binary mobile phase consisting of water containing 0.1% (v/v) formic acid (A) and acetonitrile also with 0.1% (v/v) formic acid (B). A gradient program was used as follows: 0–1 min, 15% B; 1–3 min, 15–25% B; 3–13 min, 25–40% B; 13–15 min, 40–95% B; 15–18 min, 95% B. The flow rate was 0.3 mL.min-1 and the sample injection volume was 2 µL.
Operating conditions for the HESI source used in a negative ionization mode were: -2.5 kV spray voltage, 320 °C capillary and probe heater temperature, sheath gas flow rate 38 a.u., auxiliary gas flow 12 a.u. (a.u. refer to arbitrary values set by the Exactive Tune software) and S-Lens RF level 50.00. Nitrogen was used for sample nebulization and collision gas in HCD cell. The full MS mode was used as an MS experiment where the resolution, AGC target, max. IT and mass range were 70000 (at m/z 200), 3e6, 200 ms, and m/z 300–1500, respectively. Xcalibur software ver. 4.0 was used for data acquisition and processing.
The quantification of saponins was carried out using the external standard method. The amounts of saponins are relative and not absolute. Each of the saponins was dissolved in 10 mL 70 vol. % EtOH (primary solutions). The stock standard solution of six saponins was prepared by combining the aliquots (1 mL) of each primary solution and dilution to 10 mL with 70 vol. % EtOH. It was stored in the refrigerator at 4 °C. The working standard solutions of appropriate concentration were prepared by diluting the stock standard solution with 70 vol. % EtOH. External standard calibrations were established on five data points covering the concentration range of 2.016–1260 ng/mL for (1) and (2), 2–1250 ng/mL for (3), 1.792–1120 ng/mL for (4), 1.984–1240 ng/mL for (5), and 2.048–1280 ng/mL for (6).
The limit of detection (LOD) of an analytical procedure is the lowest analytical concentration at which an analyte(s) could be detected qualitatively. Typically, peak heights are two or three times the noise level. The quantitation limit (LOQ) is also the lowest concentration at that level analyte can be quantitated with acceptable precision, requiring peak heights 10 to 20 times higher than the baseline noise. This signal-to-noise ratio is a good rule of thumb. Limits of detection (LODs) were calculated according to the expression 3.3 σ/S, where σ was the standard deviation of the response and S the slope of the calibration curve. Limits of quantification (LOQs) were established from the expression 10 σ/S (
Accuracy is the closeness of the analytical results obtained by the analyses to the true values and usually presented as a percent of nominal (
The precision of an analytical method is the amount of variation in the results obtained from multiple analyses of the homogeneous samples. Intra‐day precision (repeatability), defines the precision obtained using the same operating conditions over a designated short period (typically ≤1 day). Inter‐day precision (intermediate precision), defines the precision obtained using the same operating conditions, typically within the same laboratory, over a designated period (typically ≥1 day) (
Ultra-high performance liquid chromatography – high-resolution mass spectrometry (UHPLC-HRMS) was used to detect the saponins in the crude and purified EtOH extracts of C. bonus-henricus roots in this work.
The efficiency of the extraction procedure was tested by using different solvents (80 vol. % MeOH, 50 vol. % MeOH, 70 vol. % EtOH, and 50 vol. % EtOH) and techniques (ultrasonic-assisted and magnetic stirring extractions). The results showed that the highest extraction efficiency was achieved using ultrasonic-assisted extraction with 70% EtOH.
The excellent selectivity of solid-phase extraction over RP18 and column chromatography over Diaion HP-20 for the preparation of crude and purified EtOH extracts helped to improve the LC-MS analysis.
The chromatographic conditions were optimized to achieve effective separation, symmetric peak shape, and short run time. Two chromatographic columns, Kromasil Eternity XT C18 column (2.1 × 100 mm, 1.8 μm) and Phenomenex Kinetex EVO C18 (100 × 2.1 mm, 1.7 μm) were pretested, and the best separation efficiency was obtained with the Kromasil Eternity XT C18 column. Acetonitrile was selected as the mobile phase due to its improved separation, and reduced column backpressure compared with methanol. The addition of formic acid in the mobile phase improved the peak shape, sensitivity, and retention time of individual saponins, which was consistent with the previous report (
Quantitative determination of the main saponins in the roots of C. bonus-henricus L. was performed by the method of the external standard. Six previously isolated saponins from a title plant were used as external standards (
The calibration curves were linear over the concentration range of 2.016–1260 ng/mL for (1) and (2), 2–1250 ng/mL for (3), 1.792–1120 ng/mL for (4), 1.984–1240 ng/mL for (5), and 2.048–1280 ng/mL for (6). All calibration curves showed very good linear regressions and the correlation coefficients were R2 > 0.99 (Table
Marker compound | Linear range (ng/mL) | Regression equations | R2 | LOD (ng/mL) | LOQ (ng/mL) |
---|---|---|---|---|---|
1 | 2.016–1260 | Y = 70407.4 + 53568.2X | 0.9976 | 0.20 | 0.61 |
2 | 2.016–1260 | Y = -188231 + 62786.2X | 0.9996 | 0.21 | 0.64 |
3 | 2.000–1250 | Y = -174018 + 23140.9X | 0.9986 | 0.61 | 1.85 |
4 | 1.792–1120 | Y = -94568 + 43512.4X | 0.9987 | 0.42 | 1.28 |
5 | 1.984–1240 | Y = 121137 + 66095.8X | 0.9993 | 0.53 | 1.62 |
6 | 2.048–1280 | Y = -41183.7+13884.9X | 0.9997 | 0.53 | 1.60 |
The method showed that LODs and LOQs were 0.20 ng/mL and 0.61 ng/mL (1), 0.21 ng/mL and 0.64 ng/mL (2), 0.61 ng/mL and 1.85 ng/mL (3), 0.42 ng/mL and 1.28 ng/mL (4), 0.53 ng/mL and 1.62 ng/mL (5), and 0.53 ng/mL and 1.60 ng/mL (6), respectively (Table
The accuracy of the analytes (1–6) was checked by addition of a standard solution mixture at three concentrations (126, 252, and 378 ng/mL for (1) and (2); 125, 250 and 375 ng/mL for (3); 112, 224 and 336 ng/mL for (4); 124, 248 and 372 ng/mL for (5); 108, 216 and 324 ng/mL for (6)) close to that expected in the real plant samples. Blank samples from the same unspiked plant material were analyzed at the same time as the spiked samples and the measured values were subtracted. Besides, the related compounds showed overall recoveries ranging from 95.38% to 103.47% with RSD ranging from 0.64% to 4.25%. A good agreement between the spiked and determined concentrations indicated acceptable accuracy (Table
Saponins | Added (ng/mL) | Founda (ng/mL) | Recoverya (%) | RSD (%) |
---|---|---|---|---|
1 | 126 | 120.18 ± 0.77 | 95.38 ± 0.61 | 0.64 |
252 | 241.18 ± 6.29 | 95.70 ± 2.50 | 2.61 | |
378 | 383.20 ± 3.44 | 101.38 ± 0.91 | 0.90 | |
2 | 126 | 124.76 ± 5.30 | 99.02 ± 4.20 | 4.25 |
252 | 241.24 ± 4.49 | 95.73 ± 1.78 | 1.86 | |
378 | 373.41 ± 4.94 | 98.79 ± 1.31 | 1.32 | |
3 | 125 | 128.83 ± 2.92 | 103.07 ± 2.34 | 2.27 |
250 | 258.00 ± 3.08 | 103.20 ± 1.23 | 1.19 | |
375 | 374.82 ± 3.56 | 99.95 ± 0.95 | 0.95 | |
4 | 112 | 113.68 ± 4.11 | 101.50 ± 3.67 | 3.61 |
224 | 218.79 ± 7.32 | 97.67 ± 3.27 | 3.35 | |
336 | 347.65 ± 7.34 | 103.47 ± 2.18 | 2.11 | |
5 | 124 | 121.40 ± 1.65 | 97.90 ± 1.33 | 1.36 |
248 | 242.44 ± 4.29 | 97.76 ± 1.73 | 1.77 | |
372 | 374.02 ± 7.19 | 100.54 ± 1.93 | 1.92 | |
6 | 108 | 103.90 ± 1.84 | 96.20 ± 1.70 | 1.77 |
216 | 207.56 ± 4.82 | 96.09 ± 2.23 | 2.32 | |
324 | 322.35 ± 7.13 | 99.49 ± 2.20 | 2.21 |
The precision of the retention times was determined by analyzing the calibration samples during a single day and on three different days, respectively. The RSDs of retention times of the analytes were ≤ 0.10 for intra‐day and ≤ 0.11 for inter‐day precision assays, respectively. Also, the related compounds showed overall recoveries ranging from 95.02% to 98.71% (for intra‐day and inter‐day precision assays) with RSDs from 1.57% to 3.18%. (Tables
Evaluation of intra‐day precision (repeatability) of the UHPLC-HRMS method.
Compds. | Intra‐day precision (repeatability) | |||
---|---|---|---|---|
RT ± SD (min) | RSD | Recovery ± SD (%) | RSD (%) | |
1 | 7.68 ± 0.008 | 0.10 | 97.38 ± 2.68 | 2.75 |
2 | 8.51 ± 0.006 | 0.07 | 96.36 ± 2.66 | 2.76 |
3 | 9.38 ± 0.007 | 0.07 | 95.25 ± 2.22 | 2.33 |
4 | 9.83 ± 0.004 | 0.04 | 95.07 ± 2.68 | 2.82 |
5 | 10.45 ± 0.006 | 0.05 | 98.71 ± 2.61 | 2.64 |
6 | 12.03 ± 0.007 | 0.06 | 96.71 ± 2.69 | 2.78 |
Evaluation of inter‐day precision (intermediate precision) of the UHPLC-HRMS method.
Compds. | Inter‐day precision (intermediate precision) | |||
---|---|---|---|---|
RT±SD (min) | RSD | Recovery ± SD (%) | RSD (%) | |
1 | 7.67 ± 0.007 | 0.09 | 95.89 ± 1.90 | 1.98 |
2 | 8.51 ± 0.008 | 0.10 | 95.59 ± 3.04 | 3.18 |
3 | 9.38 ± 0.010 | 0.11 | 95.29 ± 2.66 | 2.79 |
4 | 9.83 ± 0.008 | 0.08 | 95.02 ± 2.81 | 2.95 |
5 | 10.45 ± 0.008 | 0.08 | 96.74 ± 1.52 | 1.57 |
6 | 12.02 ± 0.006 | 0.05 | 95.17 ± 1.63 | 1.72 |
The developed UHPLC-HRMS method was applied for quantification of the main saponins (1–6) in the crude and purified EtOH extracts from the roots of C. bonus-henricus L. The results show that the saponins of medicagenic acid (3), 2β-hydroxygypsogenin (4), and bayogenin (2) were the predominant compounds and reached 15.01%, 3.87%, 2.41% in the crude EtOH extract and 43.69%, 16.16%, 10.07% in the purified EtOH extract, respectively (Table
Content of saponins in the crude EtOH extract (CEE) and purified EtOH extract (PEE) from the roots of C. bonus-henricus L.
Compds. | Saponins | Content of saponins (%) | |
---|---|---|---|
CEE | PEE | ||
1 | Bonushenricoside A | 1.66 ± 0.004 | 6.19 ± 0.21 |
(3-O-α-L-arabinopyranosyl-phytolaccagenin-28-O-β-D-glucopyranosyl ester) | |||
2 | 3-O-β-glucuronopyranosyl-bayogenin-28-O-β-glucopyranosyl ester | 2.41 ± 0.03 | 10.07 ± 0.39 |
3 | 3-O-β-glucuronopyranosyl-medicagenic acid-28-β-xylopyranosyl(1→4)-α-rhamnopyranosyl(1→2)-α-arabinopyranosyl ester | 15.01 ± 0.12 | 43.69 ± 1.79 |
4 | 3-O-β-glucuronopyranosyl-2β-hydroxygypsogenin-28-O-β-glucopyranosyl ester | 3.87 ± 0.005 | 16.16 ± 0.65 |
5 | 3-O-L-α-arabinopyranosyl-bayogenin-28-O-β-glucopyranosyl ester | 0.75 ± 0.007 | 2.46 ± 0.03 |
6 | Bonushenricoside B | 1.20 ± 0.01 | 5.46 ± 0.13 |
(3-O-β-D-glucuronopyranosyl-2β-hydroxyoleanoic acid-28-O-β-D-glucopyranosyl ester) | |||
The total content of saponins (%) | 24.90 | 84.02 |
A novel UHPLC-HRMS method for simultaneous quantification of six saponins from the roots of the wild spinach (Chenopodium bonus-henricus L.) was developed. The optimized method was validated for specificity, the limit of detection and quantitation limit, linearity, accuracy, and precision. The saponins of medicagenic acid (3), 2β-hydroxygypsogenin (4), and bayogenin (2) were the predominant compounds. The total amount of assayed saponins was estimated to be 24.90% in the crude EtOH extract and 84.02% in the purified EtOH extract, respectively. The results demonstrate that the proposed method can be readily utilized for the quantitative determination of saponins in C. bonus-henricus roots and could be useful for the assurance of the quality of the herbal drug used in the food industry in the production of “tahin” and “white halva”.