Review Article |
|
Corresponding author: Febrina Amelia Saputri ( febrina.amelia@farmasi.ui.ac.id ) Academic editor: Ivanka Pencheva
© 2025 Febrina Amelia Saputri, Amaranggani Wikan Puspita Kenanga, Eka Ulya Zubaidah, Callista Andinie Mulyadi, Rimadani Pratiwi.
This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Citation:
Saputri FA, Kenanga AWP, Zubaidah EU, Mulyadi CA, Pratiwi R (2025) Recent updates on analytical methods for mercury determination: A review. Pharmacia 72: 1-14. https://doi.org/10.3897/pharmacia.72.e152087
|
Mercury is a heavy metal that can act as a contaminant that can be highly toxic. Exposure to mercury can pose a risk of central nervous system issues, memory loss, tremors, convulsions, sleeplessness, irritability, excessive fear, brain damage, paralysis, psychosis, and decreased self-confidence. Therefore, it is critical to provide trustworthy analytical methods for mercury detection in order to monitor the level of mercury. The purpose of this review is to offer critical perspectives on analytical techniques that can be used to determine mercury levels in environmental and biological samples. This current review focuses on the latest analytical methods that have been used for mercury determination in recent years. This review reveals that atomic absorption spectroscopy (AAS), liquid chromatography (LC), and inductively coupled plasma (ICP) are still routinely used to detect mercury levels. Spectrophotometric, immunoassay, electrochemical, and colorimetric testing methods are still being developed.
chromatography, electrochemical, environmental monitoring, mercury determination, spectroscopy
Heavy metals are naturally occurring elements with high atomic weights and densities and can be considered one of the most dangerous contaminants (
Mercury has the chemical symbol Hg (Hydragryum). It is a heavy metal with atomic number 80 and a molecular mass of 200.59 g/mol. Mercury dissolves easily in sulfuric acid and is resistant to alkaline pH conditions. The density of mercury is 13.5 g/cm3, which is the highest density compared to all liquid objects. Mercury metal has a heavy, silvery-white color and is odorless at room temperature (
Mercury emissions into the atmosphere were primarily caused by various industrial processes, including coal-burning, production of cement, iron and steel production, waste disposal, and direct production of mercury (
A rising concern for the toxicity of mercury highlights the need to perform an analysis of mercury. Mercury is present in various samples, which warrants a specific pretreatment and analytical techniques.
Atomic absorption spectroscopy, fluorescence spectroscopy, UV-Vis spectroscopy, inductively coupled plasma mass spectrometry, resonance scattering spectroscopy, and electrochemical methods are among the analytical methods that can be used to detect mercury (
Mercury exists in various forms of matrices in the environment. Prior to the analysis, mercury must be released from the matrices to prevent interferences during the process (Fig.
The presence of mercury in the environment can harm humans because of the risk of toxicity and even death. To ensure safety, regulatory authorities establish maximum residue limits (MRLs) for mercury in various samples. Analytical techniques such as colorimetric assay, spectrophotometric, electrochemical analysis, and chromatographic analysis are used to detect and quantify mercury in samples. Novel miscellaneous techniques have also been developed in recent years, such as using deep eutectic solvent, resins, and polymers to preconcentrate the samples. Fig.
A colorimetric assay is a method to detect analytes in a sample by causing a visible color change (
| No | Sample | Chromogenic reagent | Signal readout | Color change | LoD | Ref. |
|---|---|---|---|---|---|---|
| 1 | Water | Boronic acid-functionalized MoS2 QDs | Fluorescence (under UV lamp by naked eye) | Blue fluorescence | 1.8 nmol/L | ( |
| 2 | Soil | Nitric acid, sulfuric acid, deionized water | Microfluidic paper-based analytical devices (µPADs) | Analysis was done using software | 50–350 mg L−1 | ( |
| 3 | River water | AgNPs (AgNO3 with ascorbic acid as a reductant) | Smartphone application | Yellowish brown to colorless | 0.86 ppb | ( |
| 4 | Water | SERS-Active peroxidase-like Au@AgPt NPs | Colorimetric /SERS dual-mode detection | Colorless to blue | 0.52 μM by naked eye 0.28 nM by SERS | ( |
| 5 | Water | Ag NPs-tryptophan nanoconjugate functionalized with 3-(trimethoxysilyl) propyl methacrylate (TMPM) | UV-Vis | Yellow to colorless | 2 nM | ( |
| 6 | Water | Achillea wilhelmsii-mediated AgNPs (Aw-AgNPs) | Smartphone application | Brown to colorless | 0.30 × 10−6 M | ( |
| 7 | Water | Green tea-mediated AgNPs | UV-Vis | Brown to colorless | – | ( |
| 8 | Face cream | AgNPs-C. canephora fruit skin extract | UV-Vis | Dark brown to colorless | 0.039 mg/L | (Sulistyart et al. 2023) |
| 9 | Water | Green tea-mediated AgNPs | UV-Vis | Brown to colorless | 0.01 mg/L | ( |
| 10 | Water | Bromelain enzyme (brn-AuNPs) | Image analysis | Red to blue | 0.011 ppm | ( |
| 11 | Water | Cyanuric acid (CA-AuNPs) | Visual and/or ImageJ software | Pink to bluish purple | 0.05 µM | ( |
Microfluidic paper-based analytical devices (µPADs) and reagent-impregnated paper strips/devices are low-cost tools used for analysis without the need for complex equipment. To make µPADs, patterns are drawn on paper using hydrophobic materials to control fluid movement. Some paper-based devices for mercury detection use colorimetric methods and can detect mercury ions (Hg2+) through photographic analysis (
The current development of sensors is frequently based on nanoparticles, which are integrated with chromogenic reagents. Due to their size- and shape-dependent optical, chemical, and biological properties, nanoparticles formulated with noble metals such as gold (Au) and silver (Ag) have been developed widely, including for mercury monitoring (
Using silver nanoparticles (AgNPs), Firdaus M. et al. created a portable analytical technique for mercury ion measurement (
Song C et al. proposed a novel method using a combination of colorimetric and surface-enhanced Raman scattering (SERS) to achieve a rapid and sensitive detection of mercury (
Another approach using nanoparticles for mercury detection was applied by Balasurya S et al. Colorimetric detection of mercury ion was done in ambient water samples with Ag NPs-tryptophan nanoconjugate combined with 3-(Trimethoxysilyl)propyl methacrylate (TMPM) to colorimetrically detect mercury ions in ambient water samples (
Despite the numerous advantages of nanoparticles, the method of producing AgNPs needed costly chemical raw materials and purification due to harsh reaction conditions and the need for reducing agents such as thiols, NaBH4, and NaOH (
The development of green, sustainable silver nanoparticles has been studied extensively using various plant extracts, such as Achillea wilhelmsii (
Detection of mercury ions was done by observing the color change visually unaided. When the AgNPs solution is exposed to mercury ions, the solution turns from brown into colorless. Concentration-dependent gradient color change enables quantitative analysis of mercury using silver nanoparticles. In the research conducted by Mavaei et al., a smartphone application was used as a portable detector for the visual and quantitative analysis. The HSV (hue saturation value) assessment system was used for the detection in the application. The constructed paper-based sensor was proven to be useful for the analysis of Hg2+ pollutants in diverse real water samples with a limit of detection of 0.30 × 10−6 M (
UV-Visible spectroscopy was used to observe the shift in strength of the surface plasmon resonance (SPR) band. It was discovered that when Hg2+ salt solutions were introduced, the color of the AgNPs solution changed from brownish to transparent, and the SPR frequency for Hg2+ vanished completely. The addition of 20–160 μM Hg2+ to the AgNPs solution allowed for quantitative detection of the mercury ion. Patra S et al. also use green tea extract-mediated AgNPs to produce monodispersed AgNPs. AgNPs were found to interact with Hg2+ ions, forming a Hg − Ag alloy (amalgam), resulting in a color change from brown to no color in the sample. The sensing system has a detection limit of 0.01 mg/L and a quantification limit of 0.04 mg/L, as proven by UV-vis spectroscopy (
Another approach for green production of nanoparticles was from Suhaidi N et al., who synthesized gold nanoparticles containing the bromelain enzyme (brn-AuNPs) from Ananas comosus (
The recent colorimetry analysis of mercury was conducted by Saputri et al., which used paper immobilized by gold nanoparticles (AuNPs) conjugated with cyanuric acid (CA). The CA-AuNPs filter paper sensor’s reaction to exposure to Hg2+ is seen in the obvious color shift from pink to bluish purple. The detection limit is 0.05 µM, and it can be visually viewed with the unaided eye and/or ImageJ software. After testing with various metal ions, the colorimetric response of the sensor was also selective towards Hg2+ (
The spectrophotometric approach is extensively used to identify analytes in samples by measuring the sample’s absorbance, which indicates the analyte’s concentration (
The UV-Vis spectrophotometric method for mercury analysis is favorable because of the low-cost and easily accessible instrument. However, the analysis usually requires a reagent to form a complex with mercury that can be detected in the UV/Vis region (
The cold vapor-atomic absorption spectrometry (CV-AAS) approach was used by Koesmawati et al. for total mercury analysis in fish samples, using sodium borohydride as a reducing agent. A commonly used method by the US Environmental Protection Agency (US EPA) uses stannous chloride (SnCl2) as a reducing agent. This study found that 0.3% sodium borohydride effectively reduced Hg, and the method was successfully applied in oven-dried and freeze-dried fish meat samples, despite its susceptibility to dissolved oxygen. However, further studies should be conducted to examine the effect of different concentrations of sodium borohydride on the efficacy of the reduction of mercury (
In addition to CV-AAS, the cold vapor-atomic fluorescence spectrometer (CV-AFS) method is also used in mercury analysis. Astolfi M et al. compared CV-AFS and an advanced mercury analyzer (AMA) to measure total Hg in hair samples (
Spectrophotometric technique for the determination of mercury in the sample.
| No | Sample | Reagent | Analytical instrument used | Extraction Method | Linearity range | LOD | Ref |
|---|---|---|---|---|---|---|---|
| 1 | Water | Schiff base ligand | UV-Visible spectrophotometer | Direct measurement | 0.1–6 µg mL- 1 | 0.016 mg/L | ( |
| 2 | Fish | NaBH4 as the reductor | CV-AAS | Acid digestion | – | – | ( |
| 3 | Human hair | – | CV-AFS | Acid Digestion | 0.01–1.5 μg L−1 | 0.004 mg/kg | ( |
| 4 | Human hair | – | AMA using AAS | Does not require sample preparation | 0.1–4 ng | 0.0004 mg kg−1 | ( |
| 5 | Radioactive waste | – | DMA | Hot vapor atomic absorbance (AA) | 4 µg/L (0.4 ng) | 4 to 1000 µg/L | ( |
| 6 | Radioactive waste | Bromine monochloride and permanganate/persulfate oxidation | CV-AAS | Acid digestion | – | – | ( |
| 7 | Radioactive waste | – | ICP-MS | Acid digestion | – | – | ( |
Based on the study conducted by Looney et al., a comparison was made between direct mercury analyzer (DMA), CV-AAS, and inductively coupled plasma mass spectroscopy (ICP-MS) to determine mercury in radioactive waste samples (
One alternative to conventional methods in heavy metal analysis is to use electrochemical sensors. The electrochemical technique is known for its simplicity, rapid response, affordable cost, and portability, as well as good sensitivity for heavy metals analysis (
In analysis using electrochemical sensors, the role of electrodes is crucial in determining analytical performance; therefore, the properties and type of electrodes used must be considered (
Biomaterials such as enzymes, peptides, nucleic acids, and cells are also a popular candidate for electrode modification. Several attempts have been conducted by researchers to establish biomaterial-modified electrodes. Ri Wang et al. performed a study using GCE coated in chitosan/graphene oxide/molybdenum disulfide/Au nanoparticles (chitosan/GO/MoS2/AuNPs) and a thiolated DNA probe of the thymine-Hg2+-thymine base pair for the analysis of Hg2+ in water samples (
A study conducted by Meng et al. used single-stranded DNA so that folding into a double-stranded structure occurs in the presence of Hg2+ (
Besides biomaterials, studies were also carried out to develop an electrode that was modified using a conductive polymer. Khodaei and Zanganeh developed a GCE, which was modified usinga conductive polymer called polyaniline (PA), which was then enhanced by doping it with sulfosalicylate (SA) and creating ion-discrimination positions by patterning the PA/SA coating towards mercury (II) ions (
In addition to conductive polymers, researchers have established that metal-organic frameworks (MOFs) can also be applied to detect Hg(II) due to their excellent binding ability. The optimized MOFs used in the research conducted by Yang et al. were prepared by combining Zr(IV) and 2,5-dimercaptoterephthalic acid (Zr-DMBD MOFs) and applying it to 3D kenaf stem-derived carbon (3D-KSC) or macroporous carbon electrode (
Innovations continue to be made by Guessan et al. by modifying the carbon paste electrode (CPE) with Moringa oleifera seed powder, which is a flocculant-adsorbent used to treat water (
Furthermore, Xiaoyu Wang et al. came up with an electrochemical sensor using a rare metal, terbium vanadate (TbVO4) nanowire-based electrochemical sensor (
Electrochemical methods also allow for the detection of multiple heavy metals simultaneously. For example, Raril and Manjunatha conducted simultaneous detection of Hg(II) and Pb(II) in water and biological samples using a polyglycine-modified graphene paste electrode. The method showed sensitive results to both heavy metals and was applicable to real samples such as groundwater and blood samples with recoveries of 79.92% to 101% for Hg(II) and 86.63% to 101.2% for Pb(II) (
Electrochemical analysis for the determination of mercury in various samples.
| No | Sample | Analytical Technique | Electrode | LOD | Linearity range | Sensitivity | Ref |
|---|---|---|---|---|---|---|---|
| 1. | Tap Water | DPSV | Chitosan/GO/MoS2/AuNPs/DNA/GCE | 5.8 ng/L | 0.01 𝜇g/L – 4 𝜇g/L | – | ( |
| 2. | Sea Water | SWASV | DNA/PMET- AuNPs/PGE | 0.004 aM | 0.1 aM - 0.1 nM | – | ( |
| 3 | Sea Water | DPV | apt-pep-Au/Ag/PEDO T/GCE | 2.30 pM | 0.01 nM–100 nM | – | ( |
| 4. | River Water | DPASV | PA/SA/GCE | 1.0 × 10–10 M | 1.0 × 10–9– 1.0 × 10–4 M | – | ( |
| 5. | Waste Water | SWASV | Zr-DMBD MOFs/3D-KSC | 0.05 µM | 0.25 μM–3.5 μM | 324.58 μA/μM/cm | ( |
| 6. | Water | SWV | Sm-BTC/GCE | 10 nM | 0.01 μM–50 μM | 91.760 µA/µM/cm | ( |
| 7. | Waste Water | ASV | MO/CPE | 0.4 nM | 0.002 μM–0.009 μM | – | ( |
| 8. | Water | SWV | TbVO4/GCE | 0.18 nM | 0.01 μM–100 μM | – | ( |
| 9. | Human Blood Serum | DPV | WC NSs/SPCE | 0.19 nM | 0.002–655 μM. L−1 | 8.87 μA nM–1 L–1 cm–2 | ( |
| 10. | Water and Human Blood Serum | CV | PG/GPE | 6.6 μM | 1.5 × 10–4 to 1.5 × 10- 3 M | – | ( |
| 11. | River Water | SWASV | Au SPEs | 1.3 μg L−1 | 5−300 μg/L | – | ( |
Chromatographic analysis separates sample components based on subtle differences in solubility, resolution, adsorption, and desorption between the stationary and mobile phases (
Common extraction methods for mercury utilize solvents such as methanesulfonic acid, mercaptoethanol, L-cysteine, pepsin, and tetramethylammonium hydroxide (TMAH). Acids such as nitric and hydrochloric acid and hydrogen peroxide also can be used in the extraction process. Digestion of matrices utilized several techniques to accelerate the extraction process, such as the use of microwave heating, a closed vessel using a conventional oven, or the cold finger method, which uses a glass tube placed over the digester tube to create a reflux system that minimizes loss of analyte by evaporation (
An example of chromatographic mercury analysis uses gas chromatography-mass spectrometry (GC-MS) with derivatization using tetraaryl borate salt. A study performed by Lyu et al. successfully quantifies MeHg and EtHg bromide complexes in blood samples. The organic mercury was extracted using liquid-liquid extraction (LLE), first with a cysteine/alkaline solution, methyl isobutyl ketone (MIBK), and then with a toluene/copper chloride solution before undergoing derivatization using tetraaryl borate salt. The developed method showed a limit of detection for MeHg and EtHg bromide complexes of 0.12 ng/mL and 0.14 ng/mL, respectively (
HPLC-ICP-MS is highly preferred because it can analyze multiple elements all at once in a single run. Its seamless integration of separation and detection systems, along with its detector’s adaptability and sensitivity, makes it a versatile choice (
Due to the low concentration of mercury found in biological samples, preconcentration methods are usually required to detect them before chromatographic analysis. Over the years, many methods have been developed to extract mercury species and their various elements before chromatography analysis. One popular method is solid phase extraction (SPE), which is easy to use with liquid chromatography instruments, particularly with HPLC coupled with inductively coupled plasma mass spectrometry (HPLC-ICP-MS). It is well-tested and preferred for its high recovery, easy automation, and flexibility. The extraction techniques used can influence the choice of HPLC phase, which is important for efficiency. The SPE column used for mercury extraction from samples includes graphene oxide and carbon nanotube, with thiourea and L-cysteine as the eluting solvent. For the HPLC-ICP-MS analysis, reverse-phase is usually used in conjunction with mobile phases such as L-cysteine and 2-mercaptoethanol, combined with methanol and ammonium acetate to aid detection sensitivity and retention time.
For multielement analysis, conditions vary based on the element studied, and methods must be adapted (
A more recent approach gaining attention in recent years is dispersive liquid–liquid microextraction (DLLME). It involves dispersing an immiscible extractant phase into the sample using a dispersing agent, typically an organic solvent. DLLME offers several advantages, such as rapid extraction time, high enrichment factors, ease of use, low cost, and high extraction efficiency. However, two main disadvantages arise when using organic solvents as dispersing agents. Firstly, the partition coefficient of the analyte in the extractant phase decreases, and secondly, an organic solvent usually is not environmentally friendly (
Mercury extraction can also be achieved using natural deep eutectic solvents (NADES). a subclass of DES derived from natural sources. NADES offer advantages such as low toxicity, minimal vapor pressure, high thermal stability, ease of synthesis at ambient conditions, high purity, and cost-effectiveness. Additionally, DES is recognized as a cost-effective replacement for ionic liquids. The method developed by Ripoll et al. involves the use of a specific NADES (decanoic acid:DL-menthol 1:2) to concentrate mercury species (MeHg+, EtHg+, PheHg+, Hg2+) using DLLME before LC-UV-Vis analysis. Prior to extraction, 100 mL of dithizone solution was added to form a dithizonate-mercury complex. The LOD and LOQ of the method are 0.9 mg/L and 3 mg/L for MeHg+, EtHg+, PheHg+; and 3 mg/L and 10 mg/L for Hg2+. The environmental impact of this method is measured using the AGREEprep metric, which shows that this method is an environmentally friendly analysis method (
Chromatographic analysis used for the determination of mercury in various samples.
| No | Sample | Analytical instrument used | Extraction Method | Linearity range | LOD | Ref |
|---|---|---|---|---|---|---|
| 1 | Human hair | FC-ICP-MS | Microwave-assisted digestion | 10 μg/kg | 5.5 μg/kg | ( |
| 2 | Fish, oyster, and water | LC-ICP-MS | Magnetic solid-phase extraction | 3.2–1000, 0.55–1000 and 1.57– 1000 ng L−1 for IHg, MeHg, and EtHg | 0.96 0.17 0.47 ng/L for IHg, MeHg, and EtHg | ( |
| 3 | Water, air, biota, and sediment | LC-ICP-MS | Solid-phase extraction (SPE) | – | 0.001– 0.007 ng L | ( |
| 4 | Shark meat | UHPLC-ICP-MS | Sonication-assisted extraction | – | 0.86 pg/L | ( |
| 5 | Blood | GC-NCI-MS | Used MIBK (methyl isobutyl ketone) | 0.02 ng/mL to 20 ng/mL | 0.12 ng/mL and 0.14 ng/mL for MeHgBr and EtHgBr | ( |
| 6 | Fish, rice, and soil. | LC-ICP-MS | Microwave-assisted extraction | – | 11.2, 11.5 12.3 µg kg−1 in rice, fish, and soil | ( |
| 7 | Water | LC-ICP-MS | Magnetic solid-phase extraction | 0.26–1000 ng/L | 0.08–0.90 ng/L | ( |
| 8 | Water | LC-UV-Vis | Dispersive liquid-liquid microextraction (DLLME) | 12–200 µg L−1 | 3 µg L−1 | ( |
Current advances in mercury analysis were not limited to the common colorimetric, electrochemical, spectrophotometric, and chromatographic methods. Techniques were developed to enhance the effectiveness of mercury extraction and speciation before further analysis, such as using ion-imprinted polymers, resins, and nanosheets to aid in the sample pretreatment. A recent study also showed that silver nanoparticles (AgNPs), commonly used in the colorimetric determination of mercury, can also be used in sample preconcentration in a modified membrane.
In a study conducted by Low et al., an ion-imprinted polymer (IIP) was developed from fluorescein and 2-aminophenol functionalized methacrylic acid monomer. This IIP solution was then coated onto the quartz crystal microbalance (QCM) and assembled into the QCM-D analyzer apparatus. The IIP-QCM method was found to have a high selectivity towards Hg2+, with LOD and LOQ values of 14.17 and 42.94 ppb. The method has also been successfully applied for mercury detection in tap water and palm oil wastewater samples without further extraction processes (
Detection of mercury can also be enhanced using a new resin called CYXAD (CYPHOS 101 modified Amberlite XAD), which effectively separates different forms of mercury, including total mercury, inorganic mercury, and methylmercury in fish samples. For total mercury testing, a simple mixture of nitric acid and hydrogen peroxide helps extract mercury from the sample. For further speciation, solid-phase extraction is carried out using a cartridge containing CYXAD resin, with the assistance of hydrochloric acid and hydrogen peroxide. Determination of mercury from the extracts was then conducted using anodic stripping voltammetry (ASV). These pieces of equipment, along with their supporting appliances, are easily portable, allowing for efficient outdoor mercury testing in fish samples. This eliminates the need for lengthy extraction processes and hazardous solvents, making the testing procedure faster and more environmentally friendly (
A study by
To ensure safety, it is important to detect even small amounts of mercury, which is known to have harmful effects. A new method by Fadillah et al. designed a membrane using special filter paper modified with silver nanoparticles (AgNPs), green tea extract, and 3-amino propyl trimethoxy silane (APTMS) to preconcentrate mercury ions from cosmetic samples. Green tea extract was used as a reducing agent for AgNPs, and APTMS was added to enhance adsorption effectiveness toward Hg2+ ions. Cosmetic samples were prepared by dissolving them in HNO3 followed by heating. The solution was then filtered using the AgNPs-APTMS modified filter paper and measured using voltammetry. The result of validation showed that the method is highly sensitive, and LOD and LOQ were 0.0483 mM and 0.1611 mM, respectively (
Miscellaneous analysis used for the determination of mercury in various samples.
| No | Sample | Analytical method used | Extraction Method | Linearity range | LOD | Ref |
|---|---|---|---|---|---|---|
| 1 | Wastewater | Ion-imprinted polymer (IIP) combined with a quartz crystal microbalance (QCM) | – | 42.94 ppb to 2 ppm | 14.17 ppb | ( |
| 2 | Tuna Fish | Home-made columns called CYXAD. Determined by anodic stripping voltammetry (ASV), using a solid gold electrode (SGE) | Solid-Phase Extraction | 1.71 µA/µgL−1 and 1.68 µA/µgL−1 for HgIN CH3Hg | 0.40 µg L−1 for HgIN and 0.50 µg L−1 for CH3Hg | ( |
| 3 | Water | DSPME, followed by ICP-OES analysis | Dispersive solid-phase microextraction (DSPME) | – | 0.01 ng/mL | ( |
| 4 | Cosmetic | Membrane using voltammetry analysis | Solid-phase extraction (SPE) | – | 0.0483 mM | ( |
Mercury is a heavy metal that requires careful monitoring due to its impact on the environment and human health. Therefore, reliable analytical methods are essential for detecting and determining mercury in both environmental and biological samples. Automated analytical instruments like AAS, LC, and ICP, which utilize various detectors as well as direct detection techniques, are some of the commonly used techniques. These instruments offer excellent sensitivity, accuracy, and precision, as well as a wide application in different kinds of samples. However, a certain sample preparation method is typically required before performing the analysis. Simpler approaches, such as rapid colorimetric testing, can be used for on-site analysis but tend to be semi-quantitative. Ongoing investigations to enhance the sample preparation procedures and analytical techniques are needed in order to provide a more effective, affordable, sensitive, and environmentally friendly mercury analysis.
Conflict of interest
The authors have declared that no competing interests exist.
Ethical statements
The authors declared that no clinical trials were used in the present study.
The authors declared that no experiments on humans or human tissues were performed for the present study.
The authors declared that no informed consent was obtained from the humans, donors or donors’ representatives participating in the study.
The authors declared that no experiments on animals were performed for the present study.
The authors declared that no commercially available immortalised human and animal cell lines were used in the present study.
Funding
No funding was reported.
Author contributions
Febrina Amelia Saputri: Writing—original draft, writing—review and editing, supervision, conceptualization. Amaranggani Wikan Puspita Kenanga: Writing—original draft. Eka Ulya Zubaidah: Writing—original draft. Callista Andinie Mulyadi: Writing—review and editing. Rimadani Pratiwi: Writing—original draft, writing—review and editing, methodology.
Author ORCIDs
Febrina Amelia Saputri https://orcid.org/0000-0002-9201-8018
Data availability
All of the data that support the findings of this study are available in the main text.