Research Article |
Corresponding author: Lily Peikova ( lily_peikova@yahoo.com ) Academic editor: Plamen Peikov
© 2024 Lily Peikova, Diana Tzankova, Maria Stancheva-Zlatkova, Alexander Zlatkov.
This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Citation:
Peikova L, Tzankova D, Stancheva-Zlatkova M, Zlatkov A (2024) Development of RP-HPLC methods for the analysis of melatonin alone and in combination with sleep-enhancing dietary supplements. Pharmacia 71: 1-7. https://doi.org/10.3897/pharmacia.71.e131477
|
Melatonin, a hormone produced by the pineal gland, is widely recognized for its role in regulating sleep-wake cycles. With the increasing prevalence of sleep disorders, melatonin supplements have gained popularity as a natural remedy. Additionally, various sleep-enhancing dietary supplements combine melatonin with other active ingredients to enhance efficacy. Reliable and accurate analytical methods are essential for ensuring the quality, safety, and efficacy of these products. Reverse-phase high-performance liquid chromatography (RP-HPLC) is a powerful analytical technique widely used for the separation, identification, and quantification of compounds in complex mixtures. This article explores the development and validation of RP-HPLC methods for the analysis of melatonin, both as a single ingredient and in combination with other components in sleep-enhancing dietary supplements.
melatonin, RP-HPLC methods, sleep-enhancing dietary supplements
Melatonin, originally discovered as a hormone of the pineal gland, is produced by a wide range of organisms, including bacteria, protozoa, plants, fungi, invertebrates, and various extrapineal sites in vertebrates such as the gut, skin, Harderian gland, and leukocytes. The biosynthetic pathways of melatonin are remarkably consistent across these diverse organisms. Melatonin’s actions are pleiotropic, mediated through membrane and nuclear receptors, other binding sites, or direct chemical interactions. It plays a crucial role in regulating the sleep/wake cycle and circadian and seasonal rhythms and functions as an immunostimulator and cytoprotective agent. In vertebrates, circulating melatonin is primarily metabolized by hepatic P450 monooxygenases into 6-hydroxymelatonin, which is then excreted as 6-sulfatoxymelatonin. In the brain and other tissues, the cleavage of the pyrrole ring is more significant, producing N1-acetyl-N2-formyl-5-methoxykynuramine through enzymatic, pseudoenzymatic, photocatalytic, and free-radical reactions. Additional metabolites arise from hydroxylation and nitrosation processes. A secondary metabolite, N1-acetyl-5-methoxykynuramine, supports mitochondrial function and downregulates cyclooxygenase 2. Melatonin’s antioxidative properties, protection of mitochondrial electron flux, and neuroprotective effects have been demonstrated in numerous experimental systems. These findings suggest potential applications of melatonin as a sleep aid and in the prevention of neurodegenerative diseases (
A research study describes the synthesis of a new melatonin derivative, the evaluation of its biological properties, and the development of a novel HPLC analysis method. Initially, benzyl chloride was employed to create the new derivative, with its purity confirmed through melting point determination. The molecular structure was validated using various spectral and analytical techniques, including Fourier transform infrared (FT-IR), carbon-13 nuclear magnetic resonance (13C-NMR), differential scanning calorimetry (DSC), proton nuclear magnetic resonance (1H-NMR), and elemental analysis. The derivative’s antibacterial, antioxidant, and antitumor properties were subsequently examined through different microbial and antioxidant assays. Despite demonstrating significant antioxidant activity (APTS-99.03% and OH-99.29% compared to BHT control), the derivative exhibited limited antibacterial effects (Staphylococcus aureus inhibition zone of 7 mm) and moderate anticancer activity. The final stage involved developing an HPLC-UV method to analyze the derivative in biological samples, utilizing 64% acetonitrile at pH 4, which yielded a higher peak and shorter retention time (3.52 minutes with absorbance at 250 nm) (
Another research team developed an RP-HPLC method coupled with diode array detection to separate and quantify impurity-I (2-(5-methoxy-1H-indol-3-yl) ethanamine), impurity-II (3-(2-aminoethyl)-1H-indol-5-ol), and melatonin. The optimized mobile phase composed of 10 mMolL−¹ of sodium dihydrogenphosphate and acetonitrile (75:25 V/V) demonstrated excellent resolution, effectively separating melatonin and its impurities. Calibration curves were established for each compound: melatonin showed linearity in the concentration range of 2.5 μg mL−¹ to 7.5 μg mL−¹, impurity-I from 2.5 μg mL−¹ to 7.5 μg mL−¹, and impurity-II from 1.8 μg mL−¹ to 5.4 μg mL−¹ (
In a recent institutional clinical trial, the efficacy of immediate-release melatonin formulations in treating sleep disorders was evaluated in 40 children with autism. The study explored different daily regimens (0.5 mg, 2 mg, and 6 mg) over a one-month period. The study’s objectives were twofold: (i) to prepare low-dose melatonin hard capsules suitable for pediatric use using two complementary methods; and (ii) to conduct a stability study to determine an appropriate use-by-date. The preparation process of the melatonin hard capsules was validated based on the uniformity of mass in the capsules. A multicomponent analysis using attenuated total reflectance Fourier transformed infrared spectroscopy (ATR-FTIR) of the melatonin/microcrystalline cellulose mixture enabled the identification and quantification of both active pharmaceutical ingredients and excipients. Absolute melatonin content analysis by high-performance liquid chromatography (HPLC) revealed that the 0.5 mg and 6 mg melatonin capsules contained 93.6%±4.1% and 98.7%±6.9% of the theoretical value, respectively. A forced degradation study demonstrated effective separation of melatonin from its degradation products, with a method capability (Cpk) of 15, indicating a very low risk of false negatives (<0.01%) (
In another study, an analytical method using high-performance liquid chromatography coupled with a photodiode array detector (HPLC-PDA) was developed and validated for the determination of melatonin in poly (lactic acid) nanoparticles prepared via a single emulsion-solvent evaporation technique. The mobile phase consisted of acetonitrile and water (65:35, v/v) pumped isocratically at a flow rate of 0.9 mL/min, with detection at 220 nm using PDA. This validated HPLC-PDA method proved suitable for determining melatonin encapsulation efficiency in poly (lactic acid) nanoparticles and for assessing melatonin release profiles in vitro. Its application underscores its utility in nanoparticle characterization and in optimizing melatonin delivery systems aimed at enhancing therapeutic efficacy (
Another study outlines the development of a high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detection for the simultaneous determination of pentoxifylline and melatonin in spiked plasma samples. Chromatographic separation was achieved using an isocratic method at a temperature of 25 °C, employing a LiChrosorb® reverse phase-18 column (125 × 4.0 mm, 5 µm) as the stationary phase. The mobile phase composition consisted of water and acetonitrile in a ratio of 80:20 v/v. This method was chosen for its ability to effectively resolve and quantify both compounds of interest in plasma samples, utilizing UV detection to ensure accurate measurement (
The discovery of melatonin (Mel) in wines has sparked renewed interest in exploring the health benefits associated with wine consumption, traditionally attributed to trans-resveratrol (trans-RSV). In this context, a novel method using dispersive liquid-liquid microextraction coupled with LC-FLD (liquid chromatography with fluorescence detection) was developed for the simultaneous analysis of Mel and trans-RSV in wines. The method optimization utilized a 26-1 factorial design to identify significant variables (p < 0.05), followed by a central composite design to achieve optimal conditions: 300 µL of chloroform as the extracting solvent, 1500 µL of acetonitrile as the disperser solvent, and 1500 mg of NaCl for ionic strength. The developed method demonstrated excellent linearity (R² > 0.9999), repeatability (CV < 3.55%), and accuracy (recovery > 91.9%) when validated using blank matrix and spiked wine samples. This approach proved successful in quantifying Mel (0.63–7.44 ng mL−¹) and trans-RSV (169–2616 ng mL−¹) across various wine varieties. Comparative analysis with existing literature highlighted several advantages of the newly developed method, including improved sensitivity and robustness for detecting these bioactive compounds in wine samples (
The quest for effective protective agents against ionizing radiation has been a longstanding focus of research. While ideal radioprotectors and radiomitigators remain elusive, significant progress has been made in exploring radical scavengers as potential candidates. The primary mechanism of ionizing radiation-induced cellular damage involves free radicals, making radical scavengers a promising avenue for radioprotection. Early efforts in this field centered on synthetic thiol compounds, exemplified by amifostine (2-(3-aminopropylamino) ethylsulfanylphosphonic acid), which is FDA-approved as a radioprotector but has limited clinical indications and no nonclinical uses approved to date. Despite ongoing research and development, no new chemical entity has received FDA approval specifically as a radiation countermeasure for acute radiation syndrome (ARS). Currently, all FDA-approved radiation countermeasures, such as filgrastim (recombinant granulocyte colony-stimulating factor, G-CSF), pegfilgrastim (PEGylated form of G-CSF), and sargramostim (recombinant granulocyte macrophage colony-stimulating factor, GM-CSF), are classified as radiomitigators. These agents aim to minimize toxicity after radiation exposure rather than prevent direct damage from occurring. A clear distinction exists between radioprotectors, which are administered prior to radiation exposure to mitigate direct damage, and radiomitigators, which address toxicity post-exposure. Ongoing efforts in drug development aim to bridge this gap, with several promising molecules undergoing evaluation for both clinical and nonclinical applications. Additionally, the development of assays to assess the biological effects of ionizing radiation plays a crucial role in advancing research in this field, facilitating the evaluation of potential radioprotectors and radiomitigators. These assays provide critical insights into the efficacy and safety of candidate molecules, paving the way for future clinical applications in radiation protection and mitigation (
A straightforward, precise, rapid, and reproducible high-performance liquid chromatography (HPLC) method was developed and validated for the quantification of melatonin in capsule dosage forms, which was successfully applied for routine analysis of melatonin in capsule dosage forms. The method uses HPLC with a Diamonsil C18 column, employing a mobile phase of methanol, acetonitrile, and 0.5% acetic acid (4:1:5, v/v/v) at a 0.5 mL/min flow rate, UV detection at 250 nm, and achieving a mean recovery of 99.36% and a linearity range of 0.20–0.60 mg/mL with R = 0.99817 (
Research in Indonesia on geological materials with potential health benefits (bio-geo-prospective) is evolving, with this article proposing the exploration of melatonin from bats’ guano rock as a potential attenuator of COVID-19, considering its occurrence. Given the global pandemic and the urgent need for effective treatments, identifying and quantifying bioactive chemicals in sediment rocks, particularly medicinal compounds, through qualitative and quantitative analysis is crucial. Isolation of these active compounds can pave the way for their development into modern medicines, supported by a sensitive and validated HPLC method coupled with fluorescence detection, using direct sample extraction (DSE) to measure melatonin levels in bats’ guano rock (
RP-HPLC is a versatile and highly efficient chromatographic technique that employs a non-polar stationary phase and a polar mobile phase. It is particularly suitable for the analysis of organic molecules, including pharmaceuticals and dietary supplements. The method development process involves selecting appropriate chromatographic conditions, such as the choice of column, mobile
phase composition, flow rate, and detection wavelength to achieve optimal separation and quantification of target analytes (
Five tablets of the tested food supplement were weighed on an analytical balance and powdered using a mortar and pestle. The resulting mixture was transferred to a 100-ml volumetric flask and dissolved in methanol to the mark. The resulting solution was centrifuged for 5 min. at 2000 rpm. The supernatant was filtered first through a 0.45 µm filter and then through 0.22 µm. A sample of 20 µl of the obtained solution was injected into the HPLC system and analyzed.
Validation of the developed RP-HPLC method involves evaluating the following parameters: validation of the developed RP-HPLC method
The developed RP-HPLC method is validated with respect to the following parameters: specificity, linearity, accuracy, and precision, as required by the International Council for Harmonization (ICH).
Due to melatonin’s insolubility and poor pharmacokinetics, standard solutions of melatonin were analyzed using the developed and validated RP-HPLC procedure to identify the compound.
The developed method demonstrated linearity over a concentration range of 0.0125 μg/mL to 0.1 μg/mL. The correlation coefficient (R²) for this linearity was found to be 0.9926, indicating a strong linear relationship between the studied concentration range and the observed peak areas.
To summarize the accuracy of the analytical procedure and present the results effectively, I’ll create a table showing the recovery rates across different concentration levels, reflecting the range from 99.8% to 100.4% as mentioned. This will demonstrate the high accuracy of the method, indicating its reliability in measuring the true value of the quantity.
Here is a detailed table (Table
Concentration Level (%) | Target Concentration (µg/ml) | Measured Concentration (µg/ml) | Recovery (%) |
---|---|---|---|
25% | X/4 | 0.998X/4 to 1.004X/4 | 99.8–100.4 |
50% | X/2 | 0.998X/2 to 1.004X/2 | 99.8–100.4 |
100% | X | 0.998X to 1.004X | 99.8–100.4 |
150% | 1.5X | 0.998 * 1.5X to 1.004 * 1.5X | 99.8–100.4 |
200% | 2X | 0.998 * 2X to 1.004 * 2X | 99.8–100.4 |
The main purpose of this study was to develop an easy, selective, and accurate RP-HPLC method for the identification of melatonin in the food supplement. An analytical column, Kintex 5 µm EVO C18, 100 × 4.6 mm, was selected. During the method’s development, several mobile phases were investigated. The chemical structure of the analyte determined the following reagents and mixtures as most suitable for evaluation: methanol, acetonitrile, and phosphate buffers with different pHs. The best selectivity and resolution were achieved in the mobile phase consisting of acetonitrile and water (70:30 v/v).
The final chromatographic conditions are shown in Table
Concentration (µg/ml) | Average area (µV/ml) |
---|---|
12 | 154130 |
25 | 233679 |
50 | 627784 |
75 | 947490 |
100 | 1034585 |
125 | 1599304 |
150 | 1903719 |
RP-HPLC column Kintex 5 µm EVO C18 column (250 mm × 4.6 mm, 5 µm) Mobile phase CH3CN:H2O = 70:30 (v/v)
Wavelength: 240 nm Flow rate: 1.0 mL/min
Injection volume: 20 μl Temperature: 25 °C.
To determine the limit of detection (LOD) and limit of quantitation (LOQ) using the signal-to-noise ratio (S/N) method, we follow the guidelines set by the ICH. According to these guidelines:
The accuracy was evaluated by preparing samples at various concentration levels (25%, 50%, 100%, 150%, and 200% of the target concentration). Each concentration level was injected three times, and the results showed perfect recoveries, indicating that the method is highly accurate.
Analyses of three food supplements containing melatonin were developed. From the experiments done, it was found that the amount of melatonin in the supplements fully corresponds to the amount described on the supplement. The method was validated according to all the requirements of the ICH. The results are shown in Figs
The developed analytical method demonstrates excellent accuracy, with recovery rates ranging from 99.8% to 100.4% across various concentration levels. These results confirm that the method is capable of providing measurement results that are in close agreement with the true values, making it a reliable technique for the quantification of melatonin. The precision and reproducibility, as evidenced by the intra-daily and inter-daily standard deviations, further support the robustness of this method.
Specificity refers to the ability of the analytical method to measure the analyte response in the presence of its potential impurities, degradation products, or matrix components. For this method, specificity was assessed by evaluating the presence of interfering peaks during the retention time of melatonin and its mixtures in the blank solution.
The specificity of the developed RP-HPLC method for melatonin was confirmed, as no significant interfering peaks (peak area > 0.1%) were observed during the retention time. This indicates that the method can selectively measure melatonin without interference from other substances in the sample matrix.
The developed RP-HPLC method is specific for the analysis of melatonin and its mixtures, as evidenced by the absence of significant interfering peaks in the blank solution. This ensures that the method can accurately quantify melatonin in the presence of other components, affirming its reliability for analytical applications.
The robustness of the method was evaluated by examining the effect of small, deliberate variations in chromatographic conditions on the performance of the method. This involved adjusting parameters such as flow rate, pH of the mobile phase, column temperature, and detection wavelength to determine their impact on the results.
The variations tested included:
The method’s performance under these varied conditions was monitored by assessing parameters such as retention time, peak area, and peak shape. The results indicated that the method remained consistent and reliable under all tested conditions, confirming its robustness.
The detailed results of the robustness study are presented in Table
The present study was realized with the support of Project No. 8184/22.11.2022 from the Medical Science Council at the Medical University, Sofia.